Providing Quality Oil Care to Industry
KLEENTEK Electrostatic Liquid Cleaners (ELCs) employ a unique electrostatic cleaning system to collect all types and sizes of contaminants, providing unrivalled levels of fluid cleanliness and machine reliability. They are easily applied to the oil reservoir, circulating the oil through the cleaning chamber by its own pumping system. There are a range of different sizes to suit oil volumes and viscosities and are available to hire or buy.
Unit | Cleaning Capacity Guide, litres Hydraulic Oils, ISO VG |
Pump flow | Dimensions l x w x d (mm) |
Weight Kg |
Power Cons |
Collectors | PCs/Set | ||||
---|---|---|---|---|---|---|---|---|---|---|---|
Standard** | 32 | 46 | 68 | 100 | l/mm | W | Type | ||||
ELC-R3PSP* | EU, IS | 800 | 560 | 380 | 210 | 1.2 | 311 x 361 x 531 | 20 | 200 | CC-R3SP | 1 |
ELC-R6PSP* | EU, IS | 1600 | 1120 | 760 | 420 | 1.2 | 359 x 386 x 531 | 23 | 200 | CC-R3SP | 2 |
ELC-R10SP | CE, IS | 5000 | 3400 | 2200 | 1200 | 2.2 | 675 x 350 x 915 | 70 | 270 | CC-R10SP | 1 |
ELC-R25TP | CE, IS | 12400 | 8600 | 5800 | 3200 | 3.7 | 675 x 350 x 950 | 72 | 320 | CC-R25SP | 1 |
ELC-R50TP | CE, IS | 24000 | 16600 | 11200 | 6000 | 9 | 710 x 530 x 1080 | 108 | 760 | CC-R50SP | 1 |
ELC-R100TP | CE, IS | 48000 | 33200 | 22400 | 12000 | 12 | 1070 x 515 x 1080 | 161 | 1000 | CC-R50SP | 2 |
Standard units are suitable for Mineral Oils, PAI, Di- and Polyol Esters and Vegetable Oils (for Phosphate Esters and Polyglycols special units are available).
Standard Units available in 240V and 110V, or 3 phase on request.
Max. temperature: 60C (special units available for 80°C)
Max. viscosity : 600 cSt
Max. water content : 500ppm (=0.05%)
The above table shows the maximum oil cleaning capacity based on a continuous application. The values are approximate and are valid for normal hydraulic and lube systems.
* This type of unit is also available without a pump.
** The ELC units are manufactured in the following standards:
IS = International Standard; CE = CE marked for EU countries.
EU = dedicated units (for European machine makers)
Note for systems with servo valves the above values should be reduced by 20%
For oils with detergents/dispersants of metal or amine type the above values should be reduced. OilCare can advise accordingly.
The life of the collector is normally 2000 hours. When initially cleaning a relatively high contaminated system, the life of the collector can be reduced.